IEEE standard requirements, terminology, and test code for dry-type air-core series-connected reactors / sponsor, Transformers Committee of the IEEE Power Engineering Society.

Series-Connected dry-type air-core single-phase and three-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control flow under steady-state conditions and/or limit fault current under short-circuit conditions are covered. Dry-Ty...

Full description

Bibliographic Details
Corporate Authors: IEEE Power Engineering Society. Transformers Committee
American National Standards Institute
Institute of Electrical and Electronics Engineers
IEEE Standards Board
Language:English
Published: New York, N.Y., USA : Institute of Electrical and Electronics Engineers, 1997.
Subjects:
Physical Description:viii, 88 pages : illustrations ; 28 cm
Variant Title:
Standard requirements, terminology, and test code for dry-type air-core series-connected reactors.
Format: Book

MARC

LEADER 00000cam a2200000 a 4500
001 in00002234418
003 OCoLC
005 20220616050927.0
008 970812s1997 nyua b 000 0 eng d
020 |a 1559378816 
035 |a (OCoLC)37456474 
040 |a CWR  |c CWR  |d IRU  |d EEM  |d UtOrBLW 
049 |a EEME 
090 |a TK2551 .I24196 1997 
090 |a TK2551  |b .I24196 1997 
245 0 0 |a IEEE standard requirements, terminology, and test code for dry-type air-core series-connected reactors /  |c sponsor, Transformers Committee of the IEEE Power Engineering Society. 
246 3 0 |a Standard requirements, terminology, and test code for dry-type air-core series-connected reactors. 
260 |a New York, N.Y., USA :  |b Institute of Electrical and Electronics Engineers,  |c 1997. 
300 |a viii, 88 pages :  |b illustrations ;  |c 28 cm 
336 |a text  |b txt  |2 rdacontent 
337 |a unmediated  |b n  |2 rdamedia 
338 |a volume  |b nc  |2 rdacarrier 
500 |a "IEEE Std C57.16-1996; revision of ANSI C57.16-1958." 
500 |a "Approved 10 December 1996, IEEE Standards Board; approved 7 May 1997, American National Standards Institute." 
500 |a "13 June 1997"--Cover. 
500 |a "Recognized as an American National Standard (ANSI)." 
504 |a Includes bibliographical references. 
520 |a Series-Connected dry-type air-core single-phase and three-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control flow under steady-state conditions and/or limit fault current under short-circuit conditions are covered. Dry-Type air-core reactors covered by this standard are self-cooled by natural air convection. With some restrictions, other reactors, including filter reactors, shunt capacitor reactors (used with shunt capacitor banks), and discharge current limiting reactors (used with series capacitor banks), are also covered. 
583 1 |3 copy1  |a Committed to retain  |c 20200101  |d 20341231  |f MI-SPI  |u http://www.mcls.org/engagement/mi-spi/  |5 MiEM 
650 0 |a Electric reactors  |x Standards.  |0 http://id.loc.gov/authorities/subjects/sh85041983 
710 2 |a IEEE Power Engineering Society.  |b Transformers Committee.  |0 http://id.loc.gov/authorities/names/n84020906 
710 2 |a American National Standards Institute.  |0 http://id.loc.gov/authorities/names/n79053041 
710 2 |a Institute of Electrical and Electronics Engineers.  |0 http://id.loc.gov/authorities/names/n79053217 
710 2 |a IEEE Standards Board.  |0 http://id.loc.gov/authorities/names/n79031437 
907 |y .b33413393  |b 211113  |c 980610 
998 |a rs  |b 980604  |c m  |d a   |e -  |f eng  |g nyu  |h 0  |i 2 
935 |a BEZ2320 
999 f f |i d597d05c-a200-5c8f-b05c-4c91a09bb0ea  |s 93b187f7-f930-59cc-afc9-501a0b1120a7  |t 0 
952 f f |p Can Circulate  |a Michigan State University-Library of Michigan  |b Michigan State University  |c MSU Remote Storage  |d MSU Remote Storage  |t 0  |e TK2551 .I24196 1997  |h Library of Congress classification  |i Printed Material  |m 31293014597474  |n 1